Lat Works Construction

Above Window Lintel Repair

Above Window Lintel Repair. Window Stainless Steel Replace Lintel
This was done by a mixture of deep-pointing, where cracks were wide, and by the injection of an epoxy crack filling resin where the cracks were narrow.

Had it worked on two different times. They had to add on several feet and restore the firebox. A quote for the repairs indicated by its review was provided before any work was started. Replacing corroded window and garage door lintels that caused cracks in the brick wall. The strength and stability of walling in the size of openings in walls is limited by regulations for both solid and cavity walls. It can also be used to close up your windows or doors by providing insulation. Sometimes the lintel is simply weak and needs reinforcing to ensure there is no movement and in some cases there is no lintel at all and the masonry has simply been supported by the existing window frame.

This would have involved the removal and rebuild of all cracked brickwork and the installation of stainless steel angles above all windows. As the pressure grows, even the hardest masonry (or nut) blows apart. The reinforced bed joints form tendons that represent the upper and lower flanges of a brick beam or wall lintel. Concrete can be cast into a desired shape with desired load strength. Got an emergency with the lintels above your windows or doors?

Both types of corrosion will affect the surrounding masonry, visible in step-crack patterns, brick displacement, or window distortion under the pressure. Improperly done, repointing not only detracts from the appearance of the building, but may also cause deterioration of the masonry units themselves. This water causes rust to form on the steel which causes it to expand as it decays, sometimes up to ten times the original thickness which requires a steel lintel replacement.

You probably will not need a masonry repair or a brick crack repair at this time. The purpose of the lintel is to support the bricks facade and waterproof the wall. What is cost to replace rusted steel lintel that has caused step cracks in a brick through structural wall?

What is cost to replace rusted steel lintel that has caused step cracks in a brick through structural wall? The walls as a result have 2 stretches of cracks, one is about 10 feet vertical through stone and the other is 10 feet step wise in brick.

This is because, in this instance, the original timber windows were helping to support the outer masonry skin. Factors like cracks in the outer masonry, humidity, heavy rainfall and the freezing and thawing of cold winters wear down these steel shelves and surrounding brick, allowing moisture to seep inside and corrode the lintels.

Left untreated, rust buildup on the lintels can cause them to thicken and expand up to 10 times their original size. Questions on repairing or preventing lintel damage? A lintel may be used instead of a shelf angle. Where can you find the experts on masonry restoration and steel lintel?

Because of it cracking may occur to er ro dilate this effect of cracking we provide lintel beams. When the metal expands, it is pressing against the brick and mortar at each end, causing pressure at the weakest point. Do you need to replace cracked lintels? When the cracks are above doors and windows, the first step is to look for evidence that the lintel is cracked or blown. You will generally see vertical cracks appearing diagonally up and in from the top corners of the windows.


Lintels are horizontal members which are placed across an opening to support the portion of the structure above it. The function of …Window Lintel repair.wmv – Masonry Lintel Repair Above Window

Above Window Lintel Repair. Window Stainless Steel Replace Lintel

Irish immigrant and construction worker, encouraged his son’s entrepreneurial spirit. With traditional repair practices the time, and therefore the cost, and the disruption involved could all be considerable. For strength and stability the brickwork in the jambs of openings has to be strengthened with more closely spaced ties and the wall over the head of the opening supported by an arch, lintels or beams.

Infilling is used to fill material providing insulation, stiffness, and/or fire resistance. This process is known as rust-jacking and if left unchecked can crack apart mortar and heave bricks out of alignment. Two mortar beds, separated by 450-900mm are reinforced, each with a pair of high tensile stainless steel helical re-bars embedded into the wall with masonry repair grout.

Adding expansion joints to brick walls that cracked due to the absence of expansion joints.

Lintel Repair and Replacement in PA NJ NY CT and

Masonry Lintel Repair Above Window
The solutions to the brick problems have withstood the test of time giving us confidence that the problems have been solved and that the solutions will last a long time.

His workmen are polite, professional, always on time, and work hard all day. He is very knowledgeable about brick and stops by frequently throughout the course of the repair to check on things. Helifix system avoided the difficulty and expense of using temporary mechanical supports and the installation of new concrete lintels. Also, it had no effect on the building’s appearance. No matter what type of brickwork you need, you can count on our professional team. Scrape and sand existing rust from the lintel, coat with an exterior grade paint, caulk the joint between the lintel and material above with a poly urethane caulk.

Reinforced brick masonry can be used wherever masonry has lost its load-bearing capacity. You will first notice a small crack off the corner of the window opening, where the steel meets the sides of the brick opening and a crack in the mortar will usually stair step up the wall away from the opening.

As soon as you notice a brick or mortar crack in these areas, it is a good time to apply a masonry sealer above the openings in hopes of preventing a steel replacement repair.

Careful shoring and masonry work made this replacement process a success. Sitting between the lintel and the bricks is a layer of waterproof membrane. The lintel (top piece) also was sloped a bit to the front to drain. At this point, the raw iron will be covered with a vinyl kit specially made for fit. The lintel transfers the dead load of the wall above it to the piers on each side of the opening. Lintels may be visible or recessed in the roof of the facility, and reduce dose rate in publicly accessible areas by reducing the maze cross section.

They are fastened above a building’s windows and doors to act as a shelf for masonry. Careful inspection around your window and door openings for cracks in the upper corners or bricks, bowing over the windows or in severe cases, displacement of bricks and stones, can help you take proactive action against further lintel damage.

We will not only repair the deteriorated lintel and surrounding brick, but establish a preventative, insulated filtration system to protect your structure from future water damage.

What should you do if you notice cracks above a window or door?

With failed lintels, the cracks shouldn’t extend beyond the width of the window or door. If you are dealing with a brick flat arch lintels, you can easily carry out lintel repair with helical spiral bars.


The house below was only seven years old. Most people associate damaged lintels with older homes, but nowadays we replace lintels on houses as new as two years old. The reason for this is that new homes are often built without any flashing or the flashing is too thin above openings in brickwork or it’s installed wrong.

This allows moisture to rust unprotected steel lintel which in turn cracks the brickwork and mortar joints. Whatever amount of rust you see on the lintel, it’s five times worse behind the brickwork. There was no flashing and the lentils were left unpainted. It has been caulked and sealed but it did not solve the problems. Pump the grout to the back of the slot in a continuous even bead to approximately two thirds of the slot depth. This bar should reach around half the depth of the slot and be at least 10mm from the first bar. What grout to use in lintel repair? The best way to do this is with an inspection to appraise if there are sufficient walls ties. If you are unable to get a good view of the existing wall ties and their frequency then you can use a metal detector or an endoscope camera.

In this instance you can create a new lintel using helical bars. Installing helical bars in this way enables you to form a lintel within the existing brickwork. With the helical bar method, there is no need to replace the lintel or rebuild any of the masonry as it uses the existing brickwork.

If you have the required tools, the total costs of lintel repair can be very affordable.


Lintel Repair & Reinforcement Heliforce Bars Stronghold Preservation

Often, lintel support is insufficient; whether this is due to general deterioration of the building over time, the existing mild steel …

Leave a Reply

Your email address will not be published. Required fields are marked *